Extra

Quality used equipment
for sale

Other Special trailer - Healthcare Laboratory BENCE MAMM

Other Special trailer - Healthcare Laboratory BENCE MAMM

Basic information
Equipment CategoriesImaging Equipment
BrandOther Special trailer - Healthcare Laboratory BENCE MAMM
Year1996
LocationGrójec
CountryPoland
Pricing
Select Currency 
PricePrice on request 
Details
Serial numberBE3195
Additional informationAsset Location: Grójec, Poland.

Special semi-trailer
Purpose of the Outpatient Clinic / Healthcare Laboratory
Model / Type BENCE MAMMOGRAPHY
Year of production 1996
Serial number BE3195
Registration number BI9922A
Curb weight 10,200 kg
Technical examination date: June 24, 2021.
Bridgestone COMPASAL CPS21 11R22.5 axle tires (60% consumption)
Producer BENCE

Equipment
Type Mammograph 3000 NOVA
Year of production 2000
Serial number 03621

Type Digital Mammography Quality Control Kit
Year of production 2000
Serial number 07146

TECHNICAL DESCRIPTION
Basic accessories - no possibility to verify efficiency,
Pneumatic system (pump, lines, actuators) - no possibility to verify efficiency,
Lacquer cladding - - mechanical damage on the entire surface,
scratches, chipping of the varnish coat z
corrosion centers,
Fluid leaks - leaks found
Vehicle efficiency and completeness - no possibility to verify efficiency and
completeness
Vehicle repair and maintenance - not presented
Vehicle identification documents - presented (registration document)
Vehicle mileage documents - not presented
Basic teams:
P O D W O Z I E
Chassis components corroded with material losses.
It is not possible to check the pneumatic and braking systems.
Traces of leakage of operating fluids were found.
Wheels with corrosion centers.
Tires of wheels with cuts and material losses.
N A D W O Z I E
White body with mechanical damage on the entire surface, scratches, chipping
paint coating with corrosion centers and traces of paint repairs.
The vehicle is covered with advertising foil.
Damages needing repair / replacement:
- right side panel - broken,
- locks of left and right side compartments - damaged,
- right front side door - damaged, lowered (jammed)
- right side storage box actuator - lack,
- break room door - lock broken, cracked with material losses,
- shower - broken,
- ceiling - cracked with material losses,
- rear left side window - broken,
- 3-door wardrobe door - damaged (jammed),
- interior upholstery - dirty, contaminated,
- air conditioner housings - cracked,
- electrical installation - cut with signs of makeshift repairs.

Equipment
1 set was presented for inspection. door keys.
Send a message to the seller of this [Other] Special trailer - Healthcare Laboratory BENCE MAMM
Select contact
Arkadiusz Utnik
Inflancka 4, 00-189 Warsaw, Poland
Telephone:+48 222794781
My comment to the seller:
Name / Company: E-mail address: Phone number: Location:
Seller should answer by:e-mailphone